Fire Protection Requirements for Temporary Structures

Fire Protection Requirements for Temporary Structures

Opening scenario: A festival, a festival-goer, and a fragile line between celebration and catastrophe

It’s a sun-drenched Saturday in late spring. A city-wide festival sprawls across a park, with food trucks, stages, and a forest of tents and canopies sheltering vendors, speakers, and first-aid stations. By mid-afternoon, a sudden gust rips through a row of canopies near the main stage. A flame-retardant label tears, a fabric edge catches, and within seconds a small fire is coaxed into a bigger threat by wind. The crowd hushes as a plume of smoke spirals upward; an alert sounds, and organizers scramble to evacuate. Thankfully, a well-prepared response is in place: exit routes are clear, fire extinguishers are within reach, and the tents’ fabrics meet flame‑propagation requirements. But what if this scenario isn’t hypothetical in your city? What if temporary structures—tents, canopies, booths, pop-up stages—could become flashpoints rather than safe shelters because they aren’t built, labeled, and sited with fire protection in mind?

Temporary structures are a core feature of outdoor events, construction sites, emergency shelters, and many seasonal venues. They offer flexibility and rapid deployment, but they also introduce unique fire risks that require specialized attention. The “tent fire code” isn’t a single standard; it’s a convergence of labeling, materials, permitting, placement, and equipment requirements that vary by jurisdiction. The practical relevance for facility managers, event organizers, and safety professionals is straightforward: if you don’t plan for fire protection in these spaces, safety goals slip away, AHJs (Authorities Having Jurisdiction) lose confidence, and your event or project can be delayed or shut down.

This article provides a comprehensive, field-tested framework for understanding and applying fire protection requirements to temporary structures. We’ll cover why temporary structures are different, summarize typical regulatory expectations with concrete examples from three jurisdictions, break down the core standards you should know, provide practical checklists, and share a practical path to compliance. You’ll come away with a clear view of what “Fire Protection Requirements” means for temporary structures, how to implement them, and how 48Fire Protection can help you succeed. Throughout, you’ll see real-world citations to authorities and standards that shape best practices for tent and temporary-structure safety.

Why temporary structures demand a distinct approach to fire protection

Temporary structures are not as simple as permanent buildings with a few more tents. They present five distinctive risk profiles:

  • Variable materials and configurations: Tents, canopies, and temporary walls use fabrics and frame systems that can act differently under heat, wind, and ignition sources. Flame retardants and flame propagation labeling become critical to evaluate the overall fire behavior of the fabric.
  • Changing occupancy and use patterns: The same space may host cooking, performances, and large crowds on different days. The fire hazards shift with each use—gas cooking, heaters, lighting, or pyrotechnics may be introduced or removed.
  • Wind, weather, and structural dynamics: Temporary structures are more exposed to wind, rain, and environmental stress. Even well-secured tents can experience rapid increases in flame risk in certain wind directions or gusts.
  • Regulatory and permitting complexity: Local authorities may require a formal permit, site plans, tent diagrams, and AHJ review in advance, sometimes with explicit timing (for example, a review window before events).
  • Rapid deployment pressure: The speed of procurement and erection can tempt shortcuts—skipping testing, labeling, or adequate extinguisher provisioning if the event is near, but the risks remain high.

To address these realities, fire protection for temporary structures must combine comprehensive standards with practical, on-the-ground procedures. It’s not enough to rely on general construction codes; you need explicit attention to fabric flame propagation, labeling, extinguisher placement, egress, wind-load considerations, and timely AHJ interaction.

What the best practice looks like: a structured approach

A robust approach to temporary-structure fire protection combines the following elements:

  • Materials and labeling
  • Use fabrics and materials that have flame propagation characteristics appropriate for their use; ensure labeling per recognized standards.
  • Verify flame-retardant certifications for tent fabrics, and have documentation on hand if requested by AHJs.
  • Fire suppression and extinguishers
  • Plan extinguisher types and placement so that all occupied areas are within a specified travel distance to a suitable extinguisher.
  • Ensure extinguishers are serviced, accessible, and clearly visible with current inspection tags.
  • Fire safety planning and site control
  • Develop a site plan showing tent locations, exit paths, occupancy limits, access for emergency responders, and separation distances from ignition sources.
  • Identify ignition sources that are allowed (and prohibited) within a certain distance of tents (e.g., cooking equipment, generators).
  • Permitting and AHJ coordination
  • Initiate AHJ review well in advance of events; provide site plans, tent diagrams, and material certifications; address any concerns about occupancy, egress, and wind loads.
  • Inspection, testing, and ongoing compliance
  • Conduct pre-event inspections, verify labeling, check extinguishers, and confirm compliance with wind-speed requirements and other conditions.
  • Training and emergency readiness
  • Train staff and contractors on tent fire safety, evacuation procedures, and the proper use of extinguishers; rehearse emergency procedures with stakeholders.

Regulatory landscape: examples of jurisdictional requirements

To bring this topic into practical focus, consider three real-world examples of how jurisdictions govern tents and temporary structures. Each presents a different mix of requirements but collectively reveals the core elements you should expect to address across many venues.

  • National Capital Area Fire and Life Safety Requirements For Outdoor Events and Tent Use (National Park Service)
  • AHJ review timeline: Requires review at least 20 business days before events.
  • Documentation: Demands site plans and tent diagrams.
  • Flame propagation labeling and core standards: Mandates labeling per NFPA 701 with NFPA 1 and NFPA 101 cited as core fire-safety standards.
  • Practical implication: For large outdoor events with tents, you should plan to engage the AHJ early, provide detailed drawings, and ensure the materials meet flame-propagation and life-safety expectations. [National Capital Area Fire and Life Safety Requirements For Outdoor Events and Tent Use](https://www.nps.gov/nama/learn/management/fire-and-life-safety-requirements-for-outdoor-events-and-tent-use.htm)
  • Tents | Fairfax County Fire Marshal (Tents) (Virginia)
  • Flame-spread certification: Requires NFPA 701 flame-spread certification for tent materials.
  • Time limits: Sets a 180-day time-limit within a 12-month period with exceptions.
  • Labeling and extinguishers: Mandates NFPA 701 labeling and minimum extinguisher provisions (2A10BC), with travel-distance limits of 75 feet.
  • Practical implication: In Fairfax County, you must ensure fabric certification, maintain label visibility, and plan extinguisher provisioning and travel paths in your site layout. [Tents | Fairfax County Fire Marshal (Tents)](https://www.fairfaxcounty.gov/fire-ems/fire-marshal/tents)
  • Tents and Temporary Structures | Salt Lake City Fire Department (Utah)
  • Permitting: Requires a formal permit for tents.
  • Occupancy/space limits: Restricts placement to no more than 180 days.
  • Certification and equipment: Requires flame-retardant certification for tents and a minimum 2A10BC extinguisher within 75 feet; wind-speed requirement of 40 mph basic wind speed.
  • Practical implication: Salt Lake City’s rules emphasize permitting, duration limits, labeling/certification, extinguisher placement, and wind considerations for outdoor tents. [Tents and Temporary Structures | Salt Lake City Fire Department](https://www.slc.gov/fire/tents-and-temporary-structures/)
  • Additional NFPA guidance (for context)
  • In many jurisdictions, the core fire-safety standards include NFPA 701 for flame propagation of textiles and NFPA 101 (Life Safety Code) and NFPA 1 (Fire Code). These standards underpin labeling, fire resistance, and mitigation strategies for temporary structures. For added context, you can consult the NFPA standards detail pages:
  • NFPA 701 – Flame propagation tests for textiles and films: [NFPA 701](/detail?code=701)
  • NFPA 101 – Life Safety Code: [NFPA 101](/detail?code=101)
  • NFPA 1 – Fire Code: [NFPA 1](/detail?code=1)
  • These resources help explain why many jurisdictions insist on flame propagation labeling, extinguisher types, and egress considerations for temporary structures.

Practical requirements you’re likely to encounter for temporary structures

While local requirements vary, several core elements appear consistently across many AHJ-guided programs. The following checklist breaks them down into actionable categories.

1) Fabric and construction materials

  • Ensure fabrics used in tents and canopies have flame-retardant certification and labeling per NFPA 701 or equivalent standards recognized by the AHJ.
  • Obtain and retain documentation proving flame retardancy and compliance for each fabric component.
  • Avoid using fabrics with known high flame propagation tendencies in occupied areas or near ignition sources.

2) Labeling and documentation

  • Make NFPA 701 labeling visible on tent fabrics; maintain lab certifications on site for verification by inspectors.
  • Prepare a tent diagram that shows dimensions, anchorages, guy-lines, clearances from ignition sources, and egress paths.
  • Include a fire protection plan (FPP) or fire safety plan (FSP) as part of the event or project submittal.

3) Fire extinguishers and access

  • Position extinguishers in accordance with the governing standard (often within 75 feet for tents and temporary structures, though the distance may vary by jurisdiction).
  • Use appropriate extinguisher ratings (e.g., 2A10BC is a common minimum in some jurisdictions) and ensure they are clearly visible and accessible.
  • Verify that extinguishers are inspected, serviced, and tagged according to local requirements.

4) Site layout, egress, and access

  • Create a site plan that includes exit routes, occupancy limits, and unobstructed access for emergency responders and equipment.
  • Maintain safe separation distances between tents and from ignition sources like cooking equipment, generators, or heaters.
  • Plan for wind scenarios; ensure tents are anchored and secured to prevent collapse or displacement in gusts.

5) Permitting and AHJ coordination

  • Submit permit applications with site plans, tent diagrams, and material certifications in a timely fashion (timelines can range from weeks to months, depending on the jurisdiction).
  • Respond to AHJ questions promptly and adjust plans as needed to meet fire-safety expectations.

6) Wind, weather, and environmental controls

  • Comply with jurisdictional wind-speed requirements (e.g., basic wind-speed thresholds, such as 40 mph in some locales) for tent operations or temporary structures.
  • Implement weather-related controls, including securing tents in anticipation of gusts or storms, to prevent hazardous conditions.

7) Training and emergency readiness

  • Train staff on fire safety procedures, use of extinguishers, and evacuation plans.
  • Conduct pre-event drills or walk-throughs with staff and volunteers to minimize response times during any incident.

Table: Quick comparison of jurisdictional requirements

Jurisdiction Key fire protection requirements for tents/temporary structures Notable limits or standards Typical documentation referenced
National Capital Area (NPS) AHJ review ≥ 20 business days; site plans and tent diagrams; flame propagation labeling per NFPA 701; NFPA 1 and NFPA 101 cited AHJ-first coordination; explicit site-plan requirements Tent diagrams; labeling; NFPA 701 labeling; NFPA 1, NFPA 101 references
Fairfax County, VA NFPA 701 flame-spread certification; 180-day limit within 12 months (with exceptions); NFPA 701 labeling; minimum extinguishers 2A10BC; 75 ft travel distance Time-limited use; extinguisher placement; labeling NFPA 701 documentation; extinguisher compliance; labeling
Salt Lake City, UT Formal permit required; tents limited to 180 days; flame-retardant certification; minimum extinguisher 2A10BC within 75 ft; 40 mph wind-speed requirement Permit-based approach; wind-speed requirement Permitting records; flame-retardant certification; extinguisher placement
Common core across many jurisdictions NFPA 701 labeling; NFPA 101 and NFPA 1 references; wind and egress considerations Varies by jurisdiction, but labeling and extinguisher placement are common National and local standards references

Common mistakes and how to avoid them

  • Mistake: Assuming a tent’s label alone guarantees safety
  • Reality: A label demonstrates flame resistance but does not substitute for proper deployment, extinguishers, and egress planning. Always pair labeling with a complete fire protection plan and site-specific measures.
  • Mistake: Waiting too long to engage with the AHJ
  • Reality: Many jurisdictions require formal plan submissions and approvals well before the event date. Proactive communication helps prevent last-minute delays and rework.
  • Mistake: Underestimating extinguisher needs
  • Reality: The “minimum requirement” can be a moving target depending on occupancy, activities (e.g., cooking), and canopy size. Align extinguisher types, numbers, and locations to the actual risk profile.
  • Mistake: Overlooking wind-load and anchoring
  • Reality: Weak anchoring or insufficient enforcement of wind-load requirements can lead to tipping or tearing in gusty conditions, creating flash ignition risk.
  • Mistake: Inadequate documentation
  • Reality: Without accessible certifications and diagrams, inspectors may question compliance or request additional information, delaying occupancy.

Process: from planning to enforcement (a practical, step-by-step guide)

1) Initiate AHJ engagement early

  • Establish a point of contact with the AHJ.
  • Share a high-level plan and request initial feedback on feasibility and any known contingencies.
  • Schedule a formal review timeline that aligns with event dates.

2) Prepare site plans and tent diagrams that reflect reality

  • Create a site plan showing tent footprints, sizes, spacing, and anchor points.
  • Include tent diagrams for each structure (frame type, fabric, height, sloped sides if present).
  • Add egress routes, occupancy calculations, and access routes for emergency responders.

3) Confirm material certifications and labeling

  • Verify NFPA 701 flame propagation certification for all tent fabrics and related materials.
  • Ensure labeling is visible and legible; keep certificates on-site.

4) Plan fire safety equipment and access

  • Determine extinguisher counts and placement per the plan.
  • Confirm travel-distance requirements (e.g., within 75 feet from any point in the structure, though check local codes).
  • Plan clear access for fire and emergency vehicles.

5) Implement on-site safety measures

  • Install signage directing egress and emergency routes.
  • Maintain clear aisles and unobstructed exits; keep cooking and ignition sources separated from its respective tents.
  • Post fire-safety notices; ensure staff understand fire drill procedures.

6) Conduct pre-event inspections and testing

  • Perform a thorough pre-event inspection of fabrics, flame retardant certifications, and extinguisher tags.
  • Recheck egress paths and accessibility of extinguishers.
  • Confirm wind thresholds and any additional weather contingency plans.

7) Execute, monitor, and adjust as needed

  • During the event, monitor conditions that could impact fire safety (wind shifts, crowd density, cooking activity).
  • Be prepared to pause or relocate tents if wind or weather conditions change.

8) Post-event review and continuous improvement

  • Document any deviations, incidents, or near-misses.
  • Update procedures and documents for future events, incorporating lessons learned.

A closer look at the standards you should know

  • NFPA 701: Standard Methods of Fire Tests for Flame Propagation of Textiles and Films
  • Why it matters: Determines whether tent fabrics meet flame-propagation criteria. Tents and canopies with fabrics that fail to meet these criteria can present elevated fire hazards.
  • Practical takeaway: Demand NFPA 701 labeling for fabrics; carry copies of test results as part of the permit submittal packages.
  • NFPA 101: Life Safety Code
  • Why it matters: Provides overarching life-safety criteria for occupancy, egress, fire protection systems, and general fire‑safety concepts applicable to temporary structures that are used in occupied spaces.
  • Practical takeaway: Use NFPA 101 as a baseline for egress width, exit signage, and occupant load assumptions for tents and pop-up facilities.
  • NFPA 1: Fire Code
  • Why it matters: A comprehensive fire code that covers general fire protection, hazardous materials, and the fire department’s access requirements. It informs permit requirements and enforcement practices that can apply to temporary structures in many jurisdictions.
  • Practical takeaway: Align your fire protection plan with NFPA 1 expectations for arson-appropriate storage, ignition-source separation, and fire-extinguisher provisions.
  • Additional jurisdictional guidance
  • The three cited sources (NPS, Fairfax County, Salt Lake City) show how AHJs implement these standards with local adaptations. They illustrate common elements such as AHJ review timelines, labeling, extinguisher provisions, and wind considerations. See the following sources for practical examples:
  • National Capital Area Fire and Life Safety Requirements For Outdoor Events and Tent Use: [National Capital Area Fire and Life Safety Requirements For Outdoor Events and Tent Use](https://www.nps.gov/nama/learn/management/fire-and-life-safety-requirements-for-outdoor-events-and-tent-use.htm)
  • Tents | Fairfax County Fire Marshal (Tents): [Tents | Fairfax County Fire Marshal (Tents)](https://www.fairfaxcounty.gov/fire-ems/fire-marshal/tents)
  • Tents and Temporary Structures | Salt Lake City Fire Department: [Tents and Temporary Structures | Salt Lake City Fire Department](https://www.slc.gov/fire/tents-and-temporary-structures/)

The 48Fire Protection perspective: implementing a practical, field-ready approach

At 48Fire Protection, we specialize in turning complex fire protection requirements into clear, actionable plans for temporary structures. Our approach integrates engineering judgment with practical operations to ensure safety without slowing down your event or project. Here’s how we translate theory into results:

  • Comprehensive feasibility and planning
  • Site risk assessment: We evaluate fabric types, wind conditions, occupancy, ignition sources, and potential fire scenarios to identify risk hotspots before they arise.
  • AHJ navigation: We help you prepare permit-ready packages with site plans, tent diagrams, and material certifications, and we coordinate with AHJs to streamline approvals.
  • Fabric, labeling, and material certification services
  • Fabric certification verification: We confirm NFPA 701 labeling and other flame-resistance documentation for all fabrics and components used in tents and canopies.
  • Labeling management: We help you organize and present labeling for quick inspection, including on-site copies of test reports where required.
  • Fire suppression and equipment planning
  • Extinguisher strategy: We determine appropriate extinguisher ratings, numbers, and placements for each tent area, ensuring travel distances adhere to local guidelines.
  • Detection and alarms (where applicable): In certain contexts, we’ll design and specify lightweight detection options suitable for temporary structures, aligned with code requirements.
  • Site planning and egress optimization
  • Layout optimization: We produce site plans that reflect egress routes, occupancy calculations, and access for emergency responders.
  • Wind and weather planning: We assess wind-load implications and provide temporary anchoring recommendations to reduce risk.
  • Training, drills, and operation readiness
  • Staff training: We provide tailored fire-safety training for event staff, contractors, and volunteers to ensure familiarity with evacuation routes and extinguisher use.
  • Drills and simulations: We conduct scenario-based drills to validate readiness and identify potential gaps in procedures.
  • Documentation, records, and continuous improvement
  • Documentation suite: We maintain a complete set of permit applications, site plans, labeling documentation, and inspection checklists for audits and future events.
  • Post-event review: We conduct debriefs to capture lessons learned and refine processes for subsequent events and projects.

In practice: a worked example

Imagine a city festival with multiple tents for vendors, seating, and a stage. The planning team engages the AHJ early, and 48Fire Protection helps by:

  • Verifying NFPA 701 labeling on all tent fabrics and confirming carbon-based or other ignition sources are properly isolated from fabric surfaces.
  • Producing a detailed site plan that shows tent footprints, passageways, and recommended extinguisher locations within 75 feet of every occupied tent.
  • Coordinating with the AHJ to obtain a permit and ensuring all required documentation (including fire safety plans) is included with the submission.
  • Conducting a pre-event inspection of all materials, extinguisher tags, and egress signage. During the event, monitoring wind conditions and adjusting layout as needed.

The result is a safer event, fewer surprises, and a smoother path from planning to execution.

A note on frequency, duration, and reuse of temporary structures

  • Duration limits: Jurisdictions often impose time limits on the use of temporary structures—ranging from a few months to a set 180-day window—before a re-inspection or new permit is required. Salt Lake City’s approach (180-day cap) is a common example, reflecting the need to re-verify safety parameters for evolving weather and occupancy conditions. [Tents and Temporary Structures | Salt Lake City Fire Department](https://www.slc.gov/fire/tents-and-temporary-structures/)
  • Reuse considerations: For recurring events, establish a reusable fire protection plan template, tested labeling, and a standard permitting package to reduce cycle time while preserving safety standards.

Styling and formatting notes to keep your team aligned

  • Use bold labels for critical takeaways:
  • Key point: Flame-propagation labeling and NFPA 701 compliance are foundational for fabric used in tents.
  • Warning: Do not skip AHJ review or rely solely on generic fire suppression measures for temporary structures.
  • Pro tip: Prepare your tent diagrams and site plans weeks in advance to avoid last-minute issues with permits or inspections.
  • Checklists with [ ] checkboxes
  • [ ] NFPA 701 labeling visible on all tent fabrics
  • [ ] Site plans and tent diagrams prepared and reviewed by AHJ
  • [ ] Extinguishers positioned within 75 feet of all occupied areas
  • [ ] Wind-load and anchoring plan documented
  • [ ] Permits secured and documentation assembled
  • Tables for quick reference
  • A simple, at-a-glance comparison of jurisdictional requirements helps planners align expectations and priorities.
  • Block quotes for expert emphasis
  • “When it comes to temporary structures, you’re not just building for today; you’re building for today and the next performance, storm, and inspection,” as one safety director often notes. This principle underpins the need for a robust, repeatable process rather than piecemeal compliance.

Conclusion: bringing fire protection rigor to temporary structures

Temporary structures—tents, canopies, booths, and pop-up stages—offer the agility to host vibrant events and flexible work sites. But with that flexibility comes heightened fire risk if fabrics aren’t properly certified, if plans aren’t well-documented, and if AHJs aren’t engaged early. By understanding the core fire protection requirements—material labeling, extinguisher provisioning, site planning, and AHJ coordination—you can dramatically lower the likelihood of a fire incident or a costly permit delay.

Key takeaways

  • Expect flame-propagation labeling (NFPA 701) for tent fabrics and ensure labeling is visible. This is a recurring requirement in jurisdictions such as Fairfax County and in national guidance described by AHJs.
  • Engage the AHJ early (often well in advance of the event) and supply site plans, tent diagrams, and material certifications as part of your formal permit process.
  • Maintain clearly accessible extinguishers (common minimums such as 2A10BC), align with travel-distance and wind-speed requirements, and plan for safe egress and responder access.
  • Treat fire protection planning as a core project deliverable, not an afterthought. A robust plan reduces delays, minimizes risk, and supports safer, more successful events.
  • For event planners and facilities teams, consider collaborating with a fire-protection partner who can provide end-to-end services—from plan development through inspection and staff training—so you can focus on delivering a successful, safe experience.

A final reminder: the value of concrete, standards-based planning

Temporary structures present a distinct risk profile, but with a disciplined approach anchored in recognized standards and jurisdictional requirements, you can achieve reliable safety outcomes. The three cited sources illustrate how AHJs implement well-established fire protection principles in real settings. They show that success comes from combining documentation (site plans, diagrams, and labeling) with proactive coordination (permit submission, AHJ review) and practical readiness (extinguisher provisioning, staff training, and pre-event inspections). As you design and deploy temporary structures, remember that fire protection isn’t optional; it’s foundational to safety, compliance, and the ability to deliver events that are both exciting and safe.

References and sources

  • National Capital Area Fire and Life Safety Requirements For Outdoor Events and Tent Use. National Park Service. https://www.nps.gov/nama/learn/management/fire-and-life-safety-requirements-for-outdoor-events-and-tent-use.htm
  • Tents | Fairfax County Fire Marshal (Tents). Fairfax County, VA. https://www.fairfaxcounty.gov/fire-ems/fire-marshal/tents
  • Tents and Temporary Structures | Salt Lake City Fire Department. Salt Lake City, UT. https://www.slc.gov/fire/tents-and-temporary-structures/
  • NFPA 701 – Flame Propagation of Textiles and Films. NFPA. https://www.nfpa.org/codes-and-standards/list-of-codes-and-standards/detail?code=701
  • NFPA 101 – Life Safety Code. NFPA. https://www.nfpa.org/codes-and-standards/list-of-codes-and-standards/detail?code=101
  • NFPA 1 – Fire Code. NFPA. https://www.nfpa.org/codes-and-standards/list-of-codes-and-standards/detail?code=1

[Contact 48Fire Protection](/contact-us)

Related Posts

Share the Post: